If a motor overheats itself, the overload switch will shut off the motor for 10 minutes or so, and when the temperature reduces, you will hear the click (if you are close by and listening), as the switch resets itself. I went to check on it in the morning at about 30 min in to programmed time and motor smelt burnt and was off again. It’s no wonder malfunctions and system shortfalls occur. In most cases, an overheating motor has dead spots or hot spots on the windings and will need to be replaced with a new motor. Clean the cartridge if the filter's pressure gauge reads 8 to 10 pounds per square inch (PSI) above its normal reading (assuming your model has this gauge). Grinding or Screeching – A sign of bad bearings caused from age or rusting. Pool pumps are installed below the upper water level of the pool in pump pits or underground compartments. HydroForce ™ Rainwater Harvesting Clean Water Pump Series 3 is a submersible pressure sensitive rainwater tank pump - electronically controlled, centrifugal roto-dynamic with no reciprocating parts.Built-in non-return valve and double dry-run protection. You can rotate the dial, or shut off the pump with the breaker. Individual cross-training mini-pool with the athlete in mind. Not Pumping Water. Even brand new out of the box this would be normal operation for a pool pump (or any typical electric motor). Let it cool then heard a click. ClearO3 Ozone Water Purifying System - A Paramount Pool and Spa Systems Product - Duration: 3:09. Many inground pool pumps have trouble from time to time getting the water moving. To achieve optimal performance from the Hydro Force Ozone generator, the pool water must be as clean as possible to start with. On each end of the rotor shaft is a sealed bearing, pressed into place and removable with bearing pullers. This was my first water cooler install, and I plugged my pump into 3 x different headers (CPU, CHA, and finally PWR) and it worked fine on each. Reducing hours of operation can save money, but don’t sacrifice water quality, or you’ll need to spend more money in chemicals to compensate. If so, look under the pump to see exactly where the water is coming from. This means the pump isn't pulling water from the pool resulting in little or no water circulation in the pool. Symptoms 1. One or both may be loose and/or misaligned. This normally is preceded by a noticeable rise in the filter pressure as indicated on the gauge atop the filter canister. Does the timeclock dial spin, and keeping correct time? The pool pump; The pool filtering system; The pool chemicals; Learning how to troubleshoot these common swimming pool problems will help you save some money and keep your pool safe. 1. I forgot to mention. . 2. pressureless circulation not provided (or does not switch on) during long working breaks (with pump still running) 3. insufficient hydraulic fluid in the installation 4. coolant valve fails to switch 5. thermostat set too high 6. coolant not switched on or no coolant available, an … Does not sound like ‘surging’, when ehe pump is drawing air, sounds like more a switch problem. no obstructions. Page 27. A common problem with swimming pool pumps is when the pump will not hold a prime. The Series 3 will deliver up to 3.5 bar (household pressure is around 2.5-4.0 bar). Too thin of wire, can cause an overheating problem. Finally, incoming directional valves or check valves can break (or just be closed), blocking water flow into the pump. If the shaft spins freely, look for a bulged or cracked capacitor, or loose wire connections, or a faulty centrifugal switch (screwed onto rear of motor shaft). In cases of freeze damage or a water hammer effect, some pumps will develops cracks in the volute or pump basket housing. This is a no-brainier but if the pump isn’t working the pool water will be affected. 2. Some pumps need to be reprimed 3-4 times before they ‘catch’, so keep a bucket or garden hose handy. In order for the Hydro Spa to heat, the pump should circulate water. The heart of your circulation system, swimming pool pumps will need repair from time to time, to keep them operating in tip-top shape. Jack, flip the breaker to the pump, remove the cover on the rear of the motor, and then check for a loose switch, looking at the switch in dead center, on the end of the shaft, and also the triangle shaped switch located at 6 o’clock. Bought a used INTEX Pool Pump 2500 GPH. checked the impeller, no obstruction. Today, we’ll cover the most common pool pump problems that pool owners deal with, and some solutions you can try to bring your pool pump back online, or prevent damage. © Copyright 2020 Hearst Communications, Inc. My pool pump seems to oscillate between high and low until it overheats and shuts off. Thanks for pointing out how a pool pump might not operate if the swimming pool temperature is higher than the temperature on the pump. The procedure for priming most pool pumps is universal. Page 26 PURGE CYCLE Press this pad to activate the pump(s) If your hot tub is equipped with a second pump (P2) and/or a blower, the system will automatically activate each for 30 SINGLE PUMP SYSTEM (P1) seconds at the beginning of every filter cycle. Dual speed motors also require a dual speed timeclock, to handle the additional fourth wire, the low speed wire. Hydro-air systems can get tricky. And remember, lefty loosey, righty tighty – or turn it counter clockwise to remove the pump lid. A pool pump is no different than other electric motors in that most of the energy fed into the pump is not converted into useful mechanical energy, but instead lost from the system in the form of heat. It may be bent, or not engaging the gear behind the timer dial. Other pump noises include cavitation, when the pump is starved for water due to a clog or closed valve. If the shaft is not spinning then the bearings have frozen and locked up the shaft. PUMP NOT PUMPING FULLY. Pool pumps don’t get ‘tired’, and lose their oomph over time – there is another … If you do hear a noise, like a buzz or hum coming from the motor, this is a sign that power is reaching the motor, but is having trouble starting the motor. This sound will usually continue until the circuit breaker trips. I can’t restart it for 30-45 min… I assume after it cools. All air leaks have their origin somewhere before the pump on the suction side of the system. Debris clogging a swimming pool skimmer is a common cause of pool pump blockage. Removed motor, an still receive the same error after reset. Gus Stephens has written about aviation, automotive and home technology for 15 years. Either the pump pot or the volute can crack or warp from excessive heat. Prior to troubleshooting any pool cleaner, you should ensure that all operational equipment, including the pump filter and chlorinator, is in good working condition. Pool pumps are not overly complicated, but they can have complications. Manually priming a pump may be required when other methods fail to remove air from the lines and restore circulation. I let cool then turned back on but just overheats, tried 3 times but just keeps turning itself off. Question: if the fan blade outlet ( outside) is 90% clogged what impact can it have on the pump. Anything that disrupts that harmony may result in loss of circulation, even though the pump is physically operating. If so, replumb the pump with a new fitting and thread  sealant, or pack around the pump inlet with pool putty, and leave pump running for 24 hrs to allow putty to set up. With power off, spin the motor shaft by hand, either by turning the impeller, or accessing the shaft at the rear of the motor (loosen the capacitor to gain access to shaft with a 7/16″ wrench). Most importantly, the threaded pipe that screws into the pump can shrink or become loose over time. Get help with your Bestway Pool Heaters. It will either be leaking out along the motor shaft (shaft seal failure), or it will be leaking where the seal plate connects with the volute, caused by a loose clamp band, or misaligned o-ring. If you hear no noise when you flip the switch to turn on, no sounds at all, check the circuit breaker for the pump, and flip it off and back on again. I swapped out original wire plug with a longer one but the gauge is a little thinner then the original. : overheating ,seals ect Over time this heat creates vacuum leaks on the threaded inlet and the pump acquires another obstacle to overcome :(. If your pump is not running at ‘full head’, you can tell this by lower pressure on the filter gauge, and if you have a clear pump lid, you will see slow swirling water mixed with air. After the chamber cover is installed, and the inlet and outlet valves opened, the pump is energized. The inlet plumbing to a swimming pool pump shouldn’t ever rise above the level of the pump inlet height. The motor appears to rotate freely. Could this cause the problem? Aboveground pumps which plug into an outlet will also run 24 hrs/day, unless a small plug-in timer is utilized. The pump delivers over 2500 litres per hour using a 1" connector and … Manuals and videos for all the current Lay-Z-Spas. The strainer basket inside the pump chamber is the last-ditch filter to stop debris from entering the impeller of the pump and damaging it. If your pump is not running at ‘full head’, you can tell this by lower pressure on the filter gauge, and if you have a clear pump lid, you will see slow swirling water mixed with air. Like it’s revving a car engine. Swimming Pool Pump Turns on But Does Not Circulate Water. Finally, incoming directional valves or check valves can break (or just be closed), blocking water flow into the pump. Over time, usually 6-8 years, the bearings will wear out and begin to screech and shriek. It’s common that pool guys or homeowners really tighten down on the pump lid when screwing it on, in an effort to prevent air leaks around the pump lid o-ring. Even small pumps in regions with cheaper electricity can rack up $50 per month in energy costs for the filter pump. Hi Mike, I’m not sure. Fans or shade can help the first problem, and cleaning up around the pump (and maybe a chat with your landscaper) will solve the second problem. Or if continues, please contact Hayward Technical Services at 908-355-7995, Energy Awareness Month – 7 Ways to Save Around the Pool, Has Fall Landed in your Pool? The Association of Pool and Spa Professionals publishes standards for swimming pool circulation. A voltmeter can be used to test whether there is voltage at the pump. Swimming Pool Pump Problems. Pump motors are designed with a Thermal Overload switch, located at 12:00 as you look at the back of the motor. My pool pump runs normally, but then starts to cycle on and off. If the pump isn't cranking, but seems to turn on okay initially, check your capacitors. Pool pump problems can take many forms, and not all pump problems are …pump problems. If connected to a hose or tap, the pump will automatically start to pump water when the tap or hose is turned on. Once the pump is energized, the inlet line is under suction and the pump outlet, including the filter and return line to the pool, is under pressure. Dirty filters can also cause E02 errors to appear on the pump. Check local bylaws regarding pool usage, including fencing requirements. Shop thousands of Swimming Pool Replacement Parts from manufacturers such as Pentair, Polaris, Hayward, Jacuzzi, Sta-Rite, Pac-Fab, Jandy, and more. HI, sounds like it, motors don’t normally overheat unless there is an internal problem, assuming voltage is OK and air flow is OK around the pump. Restoring proper level in the pool should cut off the air. Swimming Pool Filter, Swimming Pool Filter Sponge Pool Filter for Intex Type S1 Reusable/Washable Swimming Pool Filter Foam Cartridge Sponge Pool Cleaner, Blue 10.8 x 7.3cm 0 Reviews Price If it flies, drives or just sits on your desk and blinks, he's probably fixed it. And it’s an urgent problem, as you can only maintain the pool clarity for a few days without the circulation pump. A tripped pool pump breaker… 1. could be a bad breaker, 2. could be a short in a wire (broken or loose or corroded wire), 3. Replacement of the specific pump parts that are cracked is easily done, or the entire pump can be replaced, if the motor is also failing, or is more than 8 years old. Hot Tub Covers & Year-Round Outdoor Spas – Cover Smart. Despite what the marketing may say, unfortunately there is no pool cleaner on the market that is 100% problem free. My pump starts, but after few seconds the breakers go off. If you have just a switch, and not a timeclock, the pump not shutting off would be a faulty or mis-wired switch. Did I get a faulty pump? Many states now require all replacement pool pumps of 1hp or more to have either dual speed or variable speed motors. The pump is the heart of a swimming pool filtration system. To ensure all air is removed from the system, the air-bleed valve on the filter should be opened. Pumps can leak water from many areas, but the prime suspects are the mechanical shaft seal and the effluent pipe fitting, the one that is screwed into the pump outlet. Aboveground pumps which are plugged into an outlet can also check the GFCI test button, to be sure that it hasn’t popped. Manufactured in the UK and designed for rainwater harvesting systems. The system then lacks enough suction to pull water through the lines and expel the air. Residential pool pumps are required to have sufficient pumping capacity to turn over the entire volume of the pool every six hours. Mike. Bad bearings are also a sign of a leaky shaft seal. In some parts of the country, pool pumps can cost a homeowner hundreds of dollars per month! Problems could be a bad capacitor, or centrifugal switch, or it could mean that the motor is ‘frozen’, from a buildup of internal rust. Drain plugs should also be tightened with thread sealant. It could also mean that the impeller or fan is clogged. We feature schematic diagrams and detailed parts lists for all types of Pool Equipment including Pool Pumps, Pool Filters, Pool Heaters, Pool Cleaners, and more. If the pressure displayed on the gauge is high, backwashing the filter according to the manufacturer’s procedure may remedy the problem. little water coming out the out take. Your pump does a great job moving water, but it’s not effective at pumping air. Pool pump motors run at around 150 degrees, too hot to touch, so a ‘hot’ motor can be considered normal. The pump housing is also known as the volute or impeller housing. Yes, that could be the problem, it should be 12 ga or 14 ga wire used for the pump cord. A neglected main pool filter may obstruct circulation entirely. Despite the RPM not being reported, I should be able to hear/see when they're not working before anything else tells me :P. But I digress. Beware that some recommendations below are dangerous. 3. Not a normal occurrence, but if the pool pump won’t shut off by the timer, have you got an ‘OFF’ dog on the timeclock (or two ‘ON’ dogs)? Burned spots or burned paint, or rusty motors may not indicate a problem with the motor, and can operate just fine internally, even when they don’t look so hot externally. Water is gravity fed to the pump inlet when the pump is off. Inside of your pump motor, the rotor spins within the stator, propelled to 3450 RPM by the alternating negative and positive attraction. Once the screws have been removed, pull the assembly out of the … But it may cause some extra work for the motor, probably. Valves, filters, skimmer baskets can all affect and be affected by, your pool pump. Page 6 If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the … Extreme Leaf Removal. Purchased and installed new 1hp raypak pump and filter system on above ground pool plummbed with 1 1/2 pvc comming from pool going to pump. You'll either have one or two, and sometimes something called a governor on the shaft end. If not an air leak (prior to the pump), it could be an obstruction in the suction pipes (main drain / skimmer), or the pump basket or impeller (or both) could be clogged with small debris.. When the LED lighting is turned off for more than 5 the hot tub. In some cases however, a motor may only overheat on very hot days with direct sunshine, or it may overheat from mulch or dirt built up around the motor vents. Could be insect infestation on wires, 4. could be wires nearly touching each other, arcing, 5. could be internal short across the windings, internal to the motor. Test it with shaving cream to see if the pump is sucking air around the incoming pipe fitting. The Association of Pool … Freeze damage from expanding ice inside the pump, or a water hammer effect caused by quickly closing off valves after the filter, or turning the filter multiport valve while the pump is running. Brand new out of the box leaking. When water begins spurting out of the bleed valve, the valve should be closed. If the filters are used for too long they will change colour and deteriorate, meaning the health of the water is not being maintained effectively. Also check for splits in the hose. You can check it again, and compare it to the error messages listed on page 33 of the EcoStar owner’s manual. With the inlet and discharge valves closed, remove the pump chamber cover and fill the chamber with water from a garden hose. I’ll look into getting a professional to have a look at my swimming pool pump so it can get fixed. 4. Any insight is appreciated. Heat is a byproduct of energy loss. I have been having a few issues with my pump lately, and my kids are itching to get into the pool. When the pump fails to circulate water, this too is often caused by a very dirty cartridge filter. When the pool pump ain’t working, ain’t nothing working. To check the impeller, turn the power off to the pump and remove the screws in the middle of the pump body. Any threads need Teflon tape, and be sure hoses are clamped tight, or if unions, be sure the o-ring is in place inside the unions. As the water source for your pump may be either above or below the pump (a tank or a bore), then the “static head” that is present is a very important part of the system. Manuals for Bestway pools including Fast Set, Splash Frame, Hydrium Steel, Power Steel and Steel Pro Frame pools. The added water primes the pump and jump-starts the suction process, which begins pulling water from the pool and expels air. The pump is the heart of a swimming pool filtration system. See if the switch in the back is loose or having trouble dis-engaging when the pump starts. Its in an open space outdoors. If the filter is too contaminated to respond to backwashing, emptying the sand or diatomaceous earth filter media, and replacement with fresh media may be required to restore full circulation. Image Credit: swimmingpool.com If your swimming pool filtration system turns on but fails to circulate water as it's supposed to, address the problem quickly, because the filter can suffer permanent damage if it continues to run without circulating water. Filter manufacturer’s specifications include the normal pressure range for your filter. Pool pumps don’t get ‘tired’, and lose their oomph over time – there is another problem at hand. Hayward SP2400VSP attempts to start, but then displays “Driver error”. That is, it shuts off for 10 to 15 seconds, runs awhile and repeats. Some pump motors can turn all sorts of colors from the heat generated by the motor, or hot spots on the windings. If it’s not regularly cleaned, a full strainer eventually may obstruct water from reaching the pump and interrupt circulation. Showroom Tour; Aquatic Collection. The pump is running since end of may and i have noticed 3-4 weeks ago the breaker tripped overnight.. did not care much and turned back on.. 2 says ago i have noticed the pool pump hasnt started in the morning and turned breaker on and this morning ( a day later) did not turn either.. breaker trips overnight. Make sure the capacitors are not bad and that the governor is closed. Loud Hum – If the shaft is spinning then it is likely the capacitor failing. General help for your Bestway pool heaters. Manuals. This could be the reason the pump is failing to operate. Debris that slips past the skimmer strainer collects here. You can paint the motor if you wish, just tape over the label, and hit it with some black Rustoleum type paint. A swimming pool’s circulation system is a closed design. If the pump still won’t turn on, check the timeclock ‘visual motor check’ on Intermatic time clocks, to look for gears turning, indicating there is power supplied to the time clock. Air infiltrating the system from various sources may accumulate in the pump chamber, where it creates an airlock and prevents sufficient water from reaching the pump to “prime” it. Since a humming noise is emanating from the pump, the pump motor shaft may not be turning on and/or the pump impeller could have ceased. If your pool pump is not starting, but instead gives a ‘hum’ or a ‘nnngh!’ type of sound, you may have a capacitor problem. Available Accessories: Bestway Replacement Filter Cartridge Type III ( 0814174), Hydro-Force Simple-Set Pump Medium (0813167), and Above Ground Pool Opening Kit (0813373) Lay-Z-Spa. As described above, check for air leaks in front of the pump, and look for any obstructions, clogged or blocked pipes or valves, before the pump. If you can’t remove the pump lid, there are lid removal tools made specifically for the purpose, or you can make your own. Paramount Pool & Spa Systems 20,646 views If the water level in the pool has dropped below the skimmer intakes, the system will draw in air. The wide range of pumps AstralPool adapts to any kind of needs of swimming pools, spas and water effects. Flipping Breaker- A deep internal component within the motor has failed and requires the motor to be replaced or rebuilt. h. Running the pump too fast or too slow. Hayward has released a new lower priced line of variable speed pumps, (around $750) – the Superpump VS and the Max-Flo VS pumps, can cut your electrical consumption by 70%, at 40% less cost than earlier generation Variable Speed models.